Network connectivity – Issues accessing resources in West US

DWN-641c5d9014Microsoft AzureStarted Impact not stated

Impact
Impact not stated
Status
Resolved after 4h 57m
Affected
us

What's happening

Watch our 'Azure Incident Retrospective' video about this incident: https://aka.ms/air/ZJV6-SGG What happened? Between 14:44 and 19:41 UTC on 23 July 2026, a subset of customers experienced connectivity failures, increased latency, and/or difficulty accessing Azure services hosted within the West US region. Impact was limited to network traffic entering or exiting the region, traffic that remained entirely within the region was not affected. Impacted services included: App Service, Application Insights, Azure AD B2C, Azure AI Bot Service, Azure AI Search, Azure API Management, Azure Application Gateway, Azure Bastion, Azure Cosmos DB, Azure Data Explorer, Azure Database for PostgreSQL, Azure Databricks, Azure ExpressRoute, Azure Firewall, Azure Kubernetes Service (AKS), Azure Monitor, Azure Speech in Foundry Tools, Azure Virtual Desktop, Azure Virtual WAN, Azure VMware Solution, Azure VPN Gateway, as well as Microsoft Sentinel and Power BI Embedded. Downstream impact to Microsoft 365 services has been communicated via MO1437424. What went wrong and why? Azure datacenters connect through redundant network paths, ensuring that traffic can continue flowing even when one path is unavailable for maintenance or repair. When unplanned maintenance – including ‘break-fix’ hardware repair – is needed on an optical device along one of these paths, the repair process starts by creating system-readable instructions, verifying that the redundant path remains healthy, and performing safety checks to confirm that the work will not affect customer traffic. Because break-fix activities on a single device are generally expected to be impactless, these requests are processed automatically without human engagement or triage. On 23 July 2026, a break-fix repair was initiated on an optical device to address a network reliability risk. A defect in our blast radius analysis system incorrectly expanded the scope of the repair event to include all optical devices egressing a specific datacenter. The safety validation step, which is designed to confirm that at least one of the two redundant datacenter paths remains available, ran but incorrectly concluded the operation was safe. The checks validated each device individually rather than evaluating the aggregate effect of isolating all devices at once, a scenario that was not accounted for because the system was never designed to process a full datacenter's worth of devices in a single request. As a result, routes were withdrawn from multiple devices simultaneously, disrupting connectivity between the datacenter and the WAN – therefore impacting traffic entering or leaving the West US region. Once the route withdrawals took effect at 14:44 UTC, physical links and routing adjacencies continued to appear healthy, which initially masked the correlation between the break-fix activity and the connectivity disruption. The impact presented as a WAN routing anomaly, as third-party networks could not reach Azure in the region, rather than as a datacenter connectivity failure. Although all physical work in the region was stopped, our engineers could not correlate to this recent change because the preparation activities in advance of the break-fix did not succeed, so the physical layer and traffic appeared healthy. Meanwhile, strong signals indicating WAN impact drew much of the investigative focus. Two parallel investigation streams developed: one focused on the WAN routing anomaly, and another examining network device health from within the datacenter. It took additional time to work past these misleading signals and eventually identify the break-fix activity as the source. It was not until 17:19 UTC that our engineers were able to correlate the routing anomaly with the break-fix activity, at which point we had identified the trigger event and began planning a rollback. Our automated recovery and rollback system detected the device failures, and attempted multiple retries to restore the affected devices

Microsoft Azure,

What to do

  1. Check whether you use Microsoft Azure in us. Check your stack.

    Drop a package.json, lockfile, Terraform or a list of domains at down.guide to see every provider you depend on.
  2. Confirm your retries, queues and scheduled jobs caught up after the 4h 57m it lasted.

    Anything that failed between 2026-07-23 14:44 UTC and 2026-07-23 19:41 UTC may need a replay.
  3. Subscribe to Microsoft Azure's feed to hear about the next one first. RSS feed.

    https://down.guide/feed?provider=azure works in Slack (/feed subscribe), Discord feed bots and any RSS reader.

Updates from Microsoft Azure 1

  1. Postmortem

    Watch our 'Azure Incident Retrospective' video about this incident: https://aka.ms/air/ZJV6-SGG What happened? Between 14:44 and 19:41 UTC on 23 July 2026, a subset of customers experienced connectivity failures, increased latency, and/or difficulty accessing Azure services hosted within the West US region. Impact was limited to network traffic entering or exiting the region, traffic that remained entirely within the region was not affected. Impacted services included: App Service, Application Insights, Azure AD B2C, Azure AI Bot Service, Azure AI Search, Azure API Management, Azure Application Gateway, Azure Bastion, Azure Cosmos DB, Azure Data Explorer, Azure Database for PostgreSQL, Azure Databricks, Azure ExpressRoute, Azure Firewall, Azure Kubernetes Service (AKS), Azure Monitor, Azure Speech in Foundry Tools, Azure Virtual Desktop, Azure Virtual WAN, Azure VMware Solution, Azure VPN Gateway, as well as Microsoft Sentinel and Power BI Embedded. Downstream impact to Microsoft 365 services has been communicated via MO1437424. What went wrong and why? Azure datacenters connect through redundant network paths, ensuring that traffic can continue flowing even when one path is unavailable for maintenance or repair. When unplanned maintenance – including ‘break-fix’ hardware repair – is needed on an optical device along one of these paths, the repair process starts by creating system-readable instructions, verifying that the redundant path remains healthy, and performing safety checks to confirm that the work will not affect customer traffic. Because break-fix activities on a single device are generally expected to be impactless, these requests are processed automatically without human engagement or triage. On 23 July 2026, a break-fix repair was initiated on an optical device to address a network reliability risk. A defect in our blast radius analysis system incorrectly expanded the scope of the repair event to include all optical devices egressing a specific datacenter. The safety validation step, which is designed to confirm that at least one of the two redundant datacenter paths remains available, ran but incorrectly concluded the operation was safe. The checks validated each device individually rather than evaluating the aggregate effect of isolating all devices at once, a scenario that was not accounted for because the system was never designed to process a full datacenter's worth of devices in a single request. As a result, routes were withdrawn from multiple devices simultaneously, disrupting connectivity between the datacenter and the WAN – therefore impacting traffic entering or leaving the West US region. Once the route withdrawals took effect at 14:44 UTC, physical links and routing adjacencies continued to appear healthy, which initially masked the correlation between the break-fix activity and the connectivity disruption. The impact presented as a WAN routing anomaly, as third-party networks could not reach Azure in the region, rather than as a datacenter connectivity failure. Although all physical work in the region was stopped, our engineers could not correlate to this recent change because the preparation activities in advance of the break-fix did not succeed, so the physical layer and traffic appeared healthy. Meanwhile, strong signals indicating WAN impact drew much of the investigative focus. Two parallel investigation streams developed: one focused on the WAN routing anomaly, and another examining network device health from within the datacenter. It took additional time to work past these misleading signals and eventually identify the break-fix activity as the source. It was not until 17:19 UTC that our engineers were able to correlate the routing anomaly with the break-fix activity, at which point we had identified the trigger event and began planning a rollback. Our automated recovery and rollback system detected the device failures, and attempted multiple retries to restore the affected devices

Reports count in aggregate; nothing about you is shown.

Questions about Network connectivity – Issues accessing resources in West US

Is Microsoft Azure still down?

No, this incident was resolved 2026-07-23 19:41 UTC. For Microsoft Azure's live state, see https://down.guide/providers/azure.

How long did it last?

4h 57m, from 2026-07-23 14:44 UTC to 2026-07-23 19:41 UTC, by the times Microsoft Azure posted.

What was affected?

Microsoft Azure named in us.

What caused it?

Microsoft Azure hasn't published a root cause. If it does, it shows here.