Check whether you use Twingate Admin Console. Check your stack
Paste a package.json, lockfile, Terraform or a list of domains at down.guide/stack to see every provider you depend on.Confirm your retries, queues and scheduled jobs caught up after the 9m it lasted.
Anything that failed between 2023-06-07 17:42 UTC and 2023-06-07 17:51 UTC may need a replay.Subscribe to Twingate's feed to hear about the next one first. RSS feed
https://down.guide/feed?provider=twingate works in Slack (/feed subscribe), Discord feed bots and any RSS reader.
Updates from Twingate 3
- investigating
We are seeing issues with our admin consoles not loading properly. It's been investigated.
provider
- resolved
This incident has been resolved. It's due to an issue with a software update. We are working on a plan to avoid this in the future. This impacted authentication flow too. Already authenticated flows continued to function.
provider
- postmortem
**Summary** On June 7th 17:08 UTC, a new version of our Controller software was rolled out. Shortly after the rollout completed, our on-call team received automated exception alerts and began investigating. The new version had inadvertently included changes to clean up our database that were out of sync with the deployed code, and the team decided to rollback the new software deployment. The rollback proceeded smoothly, however the previous code version was missing the database fields that had been cleaned up, and the incident started at 17:24 UTC. A fix was prepared and rolled out starting at 17:29 UTC. Deployment completed on the first cluster at 17:38 UTC and proceeded to the remaining clusters once we verified that the error state had been resolved. Deployment was completed on all clusters at 17:48 UTC. **Post-incident Analysis** We initially thought the incident had only impacted Admin Console users, however the following systems were impacted: * Admin Console sign in. * Client initial authentication and re-authentication requests. * Linux and container-based Connectors. This incident exposed an issue that resulted in Connectors incorrectly shutting down on transient Controller unavailability. **Root Cause** An error in our deployment process logic led to a mismatch in deployed code and database schema. **Corrective Actions** 1. Improve our processes for merging software changes that are linked to database schema changes. 2. We have fixed and will be testing the bug in our Connector uptime / retry logic. 3. Improve overall build and rollout performance to be able to push fixes more promptly.
provider
Reports count in aggregate; nothing about you is shown.
Corrections
None so far.
Something wrong on this page? Report an error or send us a note. Every fix is listed here.
Questions about DWN-2614acdc22
Is Twingate still down?
No, this incident was resolved 2023-06-07 17:51 UTC. For Twingate's live state, see https://down.guide/twingate.
How long did it last?
9m, from 2023-06-07 17:42 UTC to 2023-06-07 17:51 UTC, by the times Twingate posted.
What was affected?
Twingate named Admin Console.
What caused it?
Twingate hasn't published a root cause. If it does, it shows here.